PulseMask Pulse Lab · Aurelius Dynamic
Prototype · work in progress
Artwork PulseMask is a design study sold as wearable art — a decorative prop. It is not a respirator, not PPE, not a medical device, and it provides no protection of any kind. Every performance figure on this site is modelled, never measured.
Mission · why this exists

An honest object about an unfinished idea.

PulseMask began as a question: could a respirator be grown from a single photograph of the person who has to wear it, and could a treatment stage small enough to sit on a chin do anything real to the air passing through it?

Half of that question now has an answer. The other half does not, and this page is where the split is written down rather than smoothed over.

The geometry works. A browser tab takes a portrait and an interpupillary distance and returns 30 named, closed, printable meshes in millimetres — shell, visor frame, seal bead, inner cup, chin canister stack, valves, anchors, and a bronze-age armour layer over the top. The same engine runs headless in Node and writes the identical file. Nothing is sculpted by hand; every surface is a consequence of a parameter you can move.

The air treatment does not. At the default build the UV-C reactor delivers 0.22 mJ/cm² against a 3.0 mJ/cm² target for two-log inactivation. That is 7% of what it would need. The number is printed on the front page, in the headless readout, and here, because a study that hides its failing metric is decoration pretending to be research.

So PulseMask ships as what it honestly is today: wearable art, with the engineering left visible inside it. You can buy the files, print the piece, wear it to a show, and read every calculation that shaped it — including the one that does not close.

Scope · read this before anything else

What PulseMask is, and what it is not

Two lists. They are not marketing balance — the right-hand column is the legally and physically operative one, and it wins every disagreement with anything else on this site.

What it is

  • A wearable-art object — a costume, prop and display piece in respirator form.
  • A parametric geometry engine that generates printable STL from a portrait.
  • A published design study: the physics, the material choices and the failure modes are all written down and linked.
  • A digital product — you buy files and print them, or reserve a piece I print and assemble by hand.
  • A real-time rendering exercise — an in-browser 3D stage and a 34-design Shader Lab, both running WebGPU with TSL node materials.

What it is not

  • Not a respirator. It provides no respiratory protection whatsoever.
  • Not PPE and not personal protective equipment of any category.
  • Not a medical device, not cleared or registered by any regulator anywhere.
  • Not tested to NIOSH 42 CFR 84, EN 136, EN 143 or ISO 16900 — no protocol has been run against it at all.
  • Not validated for fit. A single photograph cannot recover metric depth. The seal conforms by construction, which is a drawing, not a measurement.
  • Not electronics. Horns, cells, PV arrays, LED rings and PZT elements are solid sculpt — no cavities, no wire routes, no emitter seats.
Never install a UV-C emitter

UV-C is a serious eye and skin hazard. The reactor is drawn fully enclosed with no line of sight to the wearer, and that geometry is the reason it can be drawn at all. Nothing sold here contains, includes or supports emitters, drivers or batteries. If you illuminate a build, use EL wire or visible LEDs only.

Current level · as of September 2026

Exactly how far along this is

Readiness on the standard nine-point technology scale. The software is further along than the device, and quoting one number for both would flatter it — so here are two.

The device — TRL 2

1
2
3
4
5
6
7
8
9

Technology concept formulated. The architecture is specified end to end and costed in physics, but no hardware has been built and no experiment has been run. Nothing has passed TRL 3 because TRL 3 requires analytical or experimental proof of the critical function — and the critical function here is germicidal dose, which currently fails by a factor of fourteen.

The generator — TRL 5

1
2
3
4
5
6
7
8
9

Validated in a relevant environment. The engine runs in two independent hosts — a browser and a headless Node process — and produces byte-identical output from the same parameters. Files it writes load and slice. What holds it below TRL 6 is the absence of an automated manifold validator: geometry is closed by construction, not closed by verification.


The numbers, unrounded

Straight from node cli.mjs --metrics-only at default parameters. These are not marketing figures and they are not rounded in our favour.

UV-C dose delivered
Against a 3.0 mJ/cm² target for 2-log inactivation. The open question of the entire project
0.22 mJ/cm² · 7% of target
Log reduction, modelled
N/N₀ = e^(−k·D), k ≈ 1.2 cm²/mJ, enveloped RNA virus at 265–280 nm. Modelled, never measured
0.11 LRV · 17 LEDs · 27.6 ms dwell
Geometry output
Named meshes at default tessellation — what actually lands in your download
30 parts · 81.2k triangles
Parts passing manifold validation
Watertight, correctly wound, no duplicate or non-manifold edges. Started at 19/30 the day the validator was written — this page had claimed all 30 were closed. All 11 failures have since been repaired and the check now runs in CI-style from the CLI. What was wrong, in the guide
30 of 30 · was 19
Shell, printed
Solid volume at SLS PA12 density, 2.6 mm wall. Moves with wall thickness and process
49 g · 48.3 cm³
Dead space
Analytic approximation of the cup envelope, not a mesh integration — flagged as an open issue
40 mL · approximate
Seal bead compression
A design value. The bead conforms to the reconstructed face by construction — this is not fit validation
0.80 mm · by construction
Solar harvest vs load
14 panels × 1.02 cm² at 22% in full sun, against UV-C LEDs at 35% wall-plug plus blower and MCU
0.32 W vs 1.48 W load
Runtime, three cases
Continuous · with full sun · with the reactor gated to inhalation only. Duty-gating is the real lever
3.5 / 4.5 / 14.8 hours

Amber and red are not styling. They mark the figures that are approximations or failures, and they stay that colour until the underlying work is done — not until the copy is rewritten.

Roadmap · seven phases

What happens next, in order

Phases are gated on evidence, not on time. Nothing moves to complete because a quarter ended. Two run in parallel right now because they are independent: one asks whether the thing fits, the other asks whether the thing works.

Phase 0
Concept & geometry
Parametric shell, inner oronasal cup, canister architecture, the in-browser generator, STL/OBJ/GLB export and the headless CLI. Done and shipping — it is what you can use today.
complete
Phase 1
Fit validation
Replace single-image inference with depth-scan capture. Print shells against a landmark panel and pressure-map them with the PZT seal array. Until this closes, every fit claim on this site stays a drawing.
in progress
Phase 2
Dose budget
Folded labyrinth reactor and blower-decoupled flow, to attack the gap between 0.22 and 3.0 mJ/cm². Bench assay with surrogate phage. This is the phase that decides whether the device half of PulseMask is ever more than art.
in progress
Phase 3
PZT validation
Isolate the ultrasonic coalescence gain and test the capsid-disruption hypothesis properly. If it does not hold up, it gets deleted from the design and from this page — not quietly downgraded to a maybe.
planned
Phase 4
Safety & interlocks
UV-C leakage survey, thermal envelope, CO₂ washout to an ISO 16900-style protocol, battery abuse testing. No physical unit with emitters exists or will exist before this phase.
planned
Phase 5
WebGPU / TSL renderer
Done. The generator and the Shader Lab both run WebGPURenderer with TSL node materials, and all 34 surface designs were rewritten from GLSL. Visual parity held, STL/OBJ/GLB exports are unaffected, and machines with no WebGPU adapter fall back to that renderer's own WebGL2 backend rather than losing the page.
complete
Phase 6
Regulatory path
Classification review and a pre-submission — only if Phases 2 and 3 produce evidence worth submitting. Until that day, no protective claim is made anywhere, and the product stays exactly what it says it is: art.
planned
Method · how the work is kept straight

The honesty contract

A design study that flatters itself is worthless, and the failure mode is not dramatic — it is one constant nudged to make a readout turn green. So the project runs under written rules that apply to me and to every automated agent that touches the repository.

No metric improves by editing a constant

The UV inactivation constant, the 55% LED coupling loss, the cell energy density, the photovoltaic efficiency, the 2.22 face-width-to-IPD ratio and the 3.0 mJ/cm² dose target are empirical or conventional values. If one is wrong it gets challenged with a citation. It never gets edited to pass a check.

Modelled is labelled modelled

Germicidal dose, log reduction, capsid disruption, coalescence gain, solar harvest and runtime are all calculated from geometry and physics. None has been measured on a bench. Every place a figure appears, that word appears with it.

Numbers are not rounded in our favour

0.22 mJ/cm² is the number. It is 7% of target and the site says so in three places. Presentation rounding is how a study becomes a brochure.

Length alone does not buy dose

For a uniformly lit tube, dose reduces to P·η·ρ·r / 2Q — a longer reactor with the same emitters delivers the same dose. The interface therefore exposes LED density, not count, so the physics cannot be gamed by dragging a slider.

The disclaimer is load-bearing

The work-in-progress badge, the artwork band at the top of every page and the "modelled, not measured" language are structural. No automated change to them ships without a human reading it first.

Fit is drawn, not proven

The seal bead is placed at a fixed offset from the reconstructed face, so it conforms by construction. That is a modelling decision. Real seal error comes from face-reconstruction error and can only be measured against a scan — which is Phase 1.

These rules live in the repository as AGENT_PLAYBOOK.md §4 and are quoted verbatim into the instructions of every agent that works on the code.

Studio

Who makes this

PulseMask is a project of Aurelius Dynamic, a one-person studio working at the seam between real-time graphics and industrial design. Pulse Lab is the hardware-shaped end of it; the same geometry and shading tooling drives the studio's other work.

Zachary Auerbach · ORCID 0009-0001-3046-9104 — an author identifier, not a mark of peer review. Nothing here has been through one.

There is no team behind the "we" on this site, and there is no company standing behind a warranty. That is precisely why the scope statement above is written as hard as it is: a sole proprietor selling a decorative object has exactly one honest position, and this is it.

The site itself follows the same discipline as the product. No analytics, no cookies, no tracking pixels, no backend, no account. Geometry is generated in your browser and never uploaded. Ordering opens a pre-addressed email or a Stripe checkout — that is the whole data pipeline.